Información básica
Modelo: DW18
Description: Flow Switch
Function: Monitors Flow In Horizontal Or Vertical Pipes
Scale Marking Options: L/h, M3/h Or US GPM
Repeatability: ±3%
Accuracy: ±15%
Measuring Tube: SS316L
Housing - Non-Ex/Ex I Versions: Polycarbonate
Housing - Ex D Version: Aluminium
Reference Relative Humidity: 60% ±15%
Process Temperature: -40…+120°C , -40…+150°C , -25…+300°C
Información adicional
Paquete: Paquete Krohne
productividad: 1000
Marca: KROHNE
transporte: Ocean,Land,Air,DHL , FedEx , UPS
Lugar de origen: Chengde
Capacidad de suministro: 10000
Certificados : CE
HS-Code: 902610000
Hafen: Dalian,Shanghai,Shenzhen
DDescripción
Los interruptores ajustables generan alarmas una vez que se alcanzan los puntos de conmutación.
Las unidades son robustas. Hay varias variantes disponibles para adaptarse a una amplia variedad de aplicaciones.
Destacar
• Tecnología probada: durante más de treinta años.
• Interruptores de láminas biestables, interruptores SPDT y relés disponibles.
• Segundo interruptor de límite opcional
• La posición del interruptor se puede ajustar en condiciones de proceso
• Adecuado para tuberías DN 15-3000 o ½ ... 120 "de diámetro
• Versión de alta temperatura (sin indicador) para condiciones de funcionamiento de hasta 300 ° C / 570 ° F
• La carcasa es removible bajo condiciones de proceso
• Aprobación opcional para aplicaciones EEx I o EEx d
• No necesita mantenimiento
Visión general
DW181 |
The DW 181 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller can have G or NPT threaded connections with sizes ranging from sup>3⁄4...2". The measuring tube and connection are made of either bronze or stainless steel (1.4404 /316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial. The DW 181 is particularly suitable for cost-effective flow detection in various applications where high accuracy is not required. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 181 is available as non-hazardous, intrinsically safe and explosion-proof version. |
DW182 |
The DW 182 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The flow controller comes with flanged connections (DN15...65 / 1⁄2...21⁄2"). The measuring tube and connection is made of stainless steel (1.4404 / 316 L). Two types of indicator are available: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial. The DW 182 is particularly suitable for cost-effective flow detection in various applications that don't require high accuracy. It can deal with flows of up to 30,000 l/h or 132.09 GPM (US). There is also a high-temperature version on offer for operating conditions up to +300°C / +570°F. The DW 182 is available as non-hazardous, intrinsically safe or explosion-proof. |
DW183 |
The DW 183 is an inline flow controller for locally indicating the flow of homogeneous clean liquids without auxiliary power. It is suitable for horizontal or vertical pipes. The device comes with flanged connections, sizes ranging from DN65...200 and 3...8". The measuring tube and connection is made of stainless steel (1.4404 / 316 L). There are two types of indicator available for this variant: a linear scale with up to two alarm positions at the top and bottom of the indicator or a dial. The DW 183 is particularly suitable for flow detection in various applications that don't require high accuracy. It can deal with flows of up to 250,000< l/h or 1101 GPM (US). It is also on offer as high-temperature version for operating conditions up to +300°C / +570°F. The DW 183 is available as non-hazardous, intrinsically-safe or explosion-proof version. |
DW184 |
The DW 184 is an insertion-type flow controller for checking the flow velocity of liquids without auxiliary power. It is suitable for horizontal and vertical pipes ≥DN250 / 10". The device comes with DN150 (PN16/40) or 6" (ASME Cl 150/300) flanges. The internals are made of stainless steel (1.4404 / 316 L). The indicator is available with a linear scale with alarm positions at the top and bottom. The DW 184 is particularly suitable for cost-effective flow detection in various applications that don't require high accuracy. It can deal with flow velocities up to 4 m/s or 13.1 ft/s. A high-temperature version can be provided for operating conditions up to +300°C / +570°F. The mechanical flow controller is available as non-hazardous, intrinsically-safe or explosion-proof version. |